A modular PLC that has room for several I/O modules is capable of being customized for a particular application.

A) True
B) False

Correct Answer

verifed

verified

Electronic components found in PLC modules


A) are not affected by electrostatic voltages.
B) can be damaged by electrostatic voltages.
C) can have their performance degraded by electrostatic voltages.
D) can be damaged by electrostatic voltages and can have their performance degraded by electrostatic voltages.

E) A) and B)
F) B) and C)

Correct Answer

verifed

verified

For the processor module shown, Block 1 represents the ___ and Block 2 the ___. For the processor module shown, Block 1 represents the ___ and Block 2 the ___.   A) input, output B) output, input C) memory, CPU D) CPU, memory


A) input, output
B) output, input
C) memory, CPU
D) CPU, memory

E) C) and D)
F) A) and C)

Correct Answer

verifed

verified

The Allen-Bradley SLC-500 address O:3/0 refers to an


A) input module in slot 3, terminal 0.
B) output module in slot 3, terminal 0.
C) input module in slot 0, terminal 3.
D) output module in slot 0, terminal 3.

E) B) and C)
F) B) and D)

Correct Answer

verifed

verified

The current sourcing sensor shown must be matched with a _____ PLC input module. The current sourcing sensor shown must be matched with a _____ PLC input module.   A) current sinking B) current sourcing C) alternating current D) either current sinking or current sourcing


A) current sinking
B) current sourcing
C) alternating current
D) either current sinking or current sourcing

E) B) and C)
F) A) and B)

Correct Answer

verifed

verified

Which of the following alarm conditions indicates that a condition is being monitored but does not have any faults present?


A) Inactive
B) Active
C) OFF
D) Acknowledged

E) C) and D)
F) A) and B)

Correct Answer

verifed

verified

The most common form of memory used to store, back up, or transfer PLC programs is


A) RAM.
B) Flash EEPROM.
C) EEPROM.
D) both Flash EEPROM and EEPROM.

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

I/O modules are designed to plug into a slot or connector.

A) True
B) False

Correct Answer

verifed

verified

For the PLC analog I/O control system shown, the fluid flow is controlled by For the PLC analog I/O control system shown, the fluid flow is controlled by   A) varying the amount of the valve opening. B) switching the valve ON and OFF. C) switching the level sensor ON and OFF. D) varying the position of the level sensor.


A) varying the amount of the valve opening.
B) switching the valve ON and OFF.
C) switching the level sensor ON and OFF.
D) varying the position of the level sensor.

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

HMI screens are developed using a software package on a PC which is downloaded into the PLC operator interface device.

A) True
B) False

Correct Answer

verifed

verified

Hot swappable I/O modules are designed to be changed with the power on and the PLC operating.

A) True
B) False

Correct Answer

verifed

verified

Which of the following specifications defines the number of field inputs or outputs that can be connected to a single module?


A) Electrical isolation.
B) Points per module.
C) Threshold voltage.
D) Current per input.

E) A) and B)
F) All of the above

Correct Answer

verifed

verified

Volatile memory elements can be classified as those that


A) do not retain stored information when the power is removed.
B) retain stored information when the power is removed.
C) do not require a battery backup.
D) both retain stored information when the power is removed and do not require a battery backup.

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

I/O modules are keyed to prevent unauthorized personnel from removing them from the I/O rack.

A) True
B) False

Correct Answer

verifed

verified

The following statement that does not apply to the optical isolator circuit used in I/O modules is that it


A) separates high-voltage and low-voltage circuits.
B) rectifies AC signals.
C) prevents damage caused by line voltage transients.
D) reduces the effect of electrical noise.

E) None of the above
F) All of the above

Correct Answer

verifed

verified

Individual outputs of a typical AC output interface module usually have a maximum current rating of about


A) 1 A or 2
B) 25 A or 50
C) 50 mA or 100 mA.
D) 250 µA or 500 µA.

E) All of the above
F) B) and C)

Correct Answer

verifed

verified

The processor may perform functions such as timing, counting, and comparing in addition to logic processing.

A) True
B) False

Correct Answer

verifed

verified

A ______ module is used to establish connections for the exchange of data.


A) thumbwheel
B) communication
C) servo
D) PID

E) A) and D)
F) B) and C)

Correct Answer

verifed

verified

One function of a PLC input interface module is to


A) accept signals from field devices and convert them into signals that can be used by the processor.
B) convert signals from the processing unit into values that can be used to control the machine or process.
C) input signals from the programming device and convert them into signals that can be used by the CPU.
D) interpret and execute the user program that controls the machine or process.

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Discrete means that each input or output has two states: true (on) or false (off).

A) True
B) False

Correct Answer

verifed

verified